XLPE Cable Hipot Test Set Power Cable High Voltage Resonant Test System

Product Details
Customization: Available
After-sales Service: Onsite and Remote Guidance
Warranty: 2 Years Free Warranty Longlife Service
Manufacturer/Factory, Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
>2000 square meters
  • XLPE Cable Hipot Test Set Power Cable High Voltage Resonant Test System
  • XLPE Cable Hipot Test Set Power Cable High Voltage Resonant Test System
  • XLPE Cable Hipot Test Set Power Cable High Voltage Resonant Test System
  • XLPE Cable Hipot Test Set Power Cable High Voltage Resonant Test System
  • XLPE Cable Hipot Test Set Power Cable High Voltage Resonant Test System
  • XLPE Cable Hipot Test Set Power Cable High Voltage Resonant Test System
Find Similar Products

Basic Info.

Model NO.
EPCZ Series
Usage
Power Cable
Cable Type
Shielded
Power
Electricity
Certification
CE
Customized
Customized
Color
Red
Output Voltage
Customized
Capacitance
Customized
Output Frequency
30 -300Hz
Resonant Voltage Waveform
Sine Wave, Waveform Distortion Rate <1.0%
Maximum Tested Product Current
1.75A 14A or Customized
Maximum Test Capacity
560kVA
Working Time
Continuous Working Time Is 60min Under Full Power
Quality Factor
30~90
Input Working Power
Three-Phase 380V
Ambient Temperature
-15~+40
Relative Humidity
<90rh%, No Condensation
Altitude
<5000m
Noise
Less Than 50dB
The System Is Consisted by
Variable Frequency Power Supply
The System Is Consisted
Exciting Transformer
Transport Package
Plywood Case with Foam and Waterproof Plastics
Specification
Customized
Trademark
EP Hipot
Origin
Wuhan, China
HS Code
9030339000
Production Capacity
500/Year

Product Description

XLPE Cable Hipot Test Set Power Cable High Voltage Resonant Test System

EPCZ Series Variable Frequency AC Resonance Test System

EPCZ Series AC Resonance Test System is specially designed for AC withstand test for electric equipments of substation at 10kV~500kV or below.

Applications:
  • Transformer
  • Cables
  • GIS System
  • Insulator
  • CT/PT
  • Generator
  • Other electric devices

Features:
  • Small size, portable for operating.
  • Screen to show the test data, status and display operation step by real-time.
  • Small temperature rising at rated load. Dry-type epoxy cast, high mechanical strength and good insulation ability.
  • 220V or 380V single phase power source is suitable for on-site sourcing.
  • Different type reactors for optional realize the multipurpose.
  • With over current, over voltage, IPM and discharge protection function.
  • Test result can be printed.

Rated output voltage: 0~500kV or below
Output frequency: 20 -300Hz.
Resonant voltage waveform: sine wave, waveform Distortion rate ≤ 1%.
Full load working time: continuous working time 60mins.
Quality factor: max. load ≥ 20.
Frequency adjustment: fineness 0.1Hz, instability ≤ 0.01%.
Power supply: 220V or 380V single-phase.

Common Configuration:
Model Test Object Main Configurations:
AC power source Exciting Transformer Reactor Capacitive Voltage Divider:
EPCZ-27/54/108-108
Test Frequency: 20~300Hz
31500kVA/35kV Power Transformer 10KW 1 unit 10KW 1 unit 27kV/1A
4 Units
Frequency: 20-300Hz
120kV
35kV circuit breaker, busbar, insulator
10kV(300mm2) cable 2000m
35kV(300mm2) cable 500m
EPCZ-54/108/216-216
Test Frequency: 20~300Hz
110kV Circuit breaker and busbar 15kW 1 unit 15kW 1 unit 54kV/1A
4 Units
Frequency: 20-300Hz
 
110kV GIS ≤ 10 intervals
35kV (300mm2) cable 1500m
10kV (300mm2) cable 3000m
110kV Full Insulated Transformer
EPCZ-65/130/260-520
Test Frequency: 20~300Hz
110kV Circuit Breaker and busbar 30KW 1 Unit 30KW 1 Unit 65kV/2A 4 Units
Frequency: 20-300Hz
300kV
110kV GIS ≤ 10 intervals
110kV (300mm2) cable 800m
35kV (300mm2) cable 3000m
10kV(300mm2) cable 200m
110kV Full Insulated Transformer
EPCZ-45/90/135/180/270-270
Test Frequency: 20~300Hz
110kV Insulator, switchgear, GIS and etc. 20kW 1 unit 20kW 1 unit 45kV/1A Six Units
Frequency: 20-300Hz
200kV
50MW/110kV Full Insulated Transformer
110kV (300mm2) cable 200m
35kV Power Transformer, switchgear, CT/PT, cable, etc.
20MW hydrogenator
10kV power transformer, switchgear, CT/PT, cables etc.
EPCZ18/36/54
Test Frequency: 20~300Hz
10kV (300mm2) cable 2000m 5KW 1 Unit 5KW 1 unit 27kV/1A    2 units or
18kV/1A    3 units
Frequency: 20-300Hz
60KV
35kV (300mm2) cable 500m
10kV power transformer, switchgear, CT/PT etc.

Note:
  • Model EPCZ-27/54/108-108, EPCZ is the model of series, 27/54/108 is: voltage of one reactor (kV)/voltage of two reactors in series connection/voltage of four reactors in series connection. 108 is the total capacity (kVA).
  • The test object is the common configuration for reference only. For details, please contact with us.
  • If the capacity of your equipment is small and voltage is too low, can add more reactors to increase the capacity, and add more divider to increase the test voltage.
More dtails on XLPE Cable Hipot Test Set Power Cable High Voltage Resonant Test System  please contact EP Hipot Electric.

XLPE Cable Hipot Test Set Power Cable High Voltage Resonant Test System
XLPE Cable Hipot Test Set Power Cable High Voltage Resonant Test System
XLPE Cable Hipot Test Set Power Cable High Voltage Resonant Test System
XLPE Cable Hipot Test Set Power Cable High Voltage Resonant Test System
XLPE Cable Hipot Test Set Power Cable High Voltage Resonant Test System
XLPE Cable Hipot Test Set Power Cable High Voltage Resonant Test System
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier