Customization: | Available |
---|---|
After-sales Service: | One or Two Years Free After Sale Service |
Warranty: | One or Two Years Free After Sale Service |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Application | CT, electromagnetic PT | |
Output | 0~180Vrms,12Arms,36A(Peak value) | |
Voltage measurement accuracy | ±0.1% | |
CT ratio measurement | Range | 1~40000 |
Accuracy | ±0.1% | |
PT ratio measurement | Range | 1~40000 |
Accuracy | ±0.1% | |
Phase measurement | Range | ±2min |
Resolution | 0.5min | |
Secondary winding resistance measurement | Range | 0~300Ω |
Accuracy | 0.2%±2mΩ | |
AC Load Measurement | Range | 0~1000VA |
Accuracy | 0.2%±0.02VA | |
Input voltage | AC220V±10%,50Hz | |
Working environment | Temperature:-10οC~50οC Humidity:≤90% |
|
Size | 340 mm×300 mm×140mm | |
Weight | <8kg |