| Customization: | Available |
|---|---|
| After-sales Service: | Remote Guidance |
| Warranty: | 1or 2 Years Free Warranty Longlife Service |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Accuracy: | Cx: | ±(read ×1%+1pF) | |
| tgδ: | ±(read ×1%+0.00040) | ||
| Anti-interference: | Frequency conversion anti-interference, under 200% interference, still can reach above accuracy. | ||
| Capacitance range: | Internal HV: | 3pF~50000pF/12kV 60pF~1μF/0.5kV | |
| External HV: | 3pF~1.5μF/12kV 60pF~30μF/0.5kV | ||
| Resolution: | Max. 0.001pF,4 significant figures | ||
| Tgδ range: | unlimited,resolution: 0.001%,capacitance, inductance, resistance can be identified automatically. | ||
| Test current range: | 10μA~5A | ||
| Inner HV: | Setting voltage range: | 0.5~12kV | |
| Max. output current: | 200mA | ||
| Increase/decrease voltage: | Continuous slide regulating | ||
| Voltage precision: | 2% | ||
| Voltage resolution: | 1V | ||
| Test frequency: | 45, 50, 55, 60, 65Hz single frequency | ||
| 45/55Hz, 55/65Hz, 47.5/52.5Hz auto double frequency conversion | |||
| Frequency precision: | ±0.01Hz | ||
| Outside HV: | UST Positive connection max. test current 5A,Power frequency or frequency conversion 40-70Hz | ||
| GST Negative connection max. test current: 12kV/5A,power frequency or frequency conversion 40-70Hz | |||
| CVT self-excitation LV output: | Output voltage 3~50V,output current 3~30A | ||
| Measuring duty: | about 36s, it depends on measuring methods | ||
| Input power supply: | 180V~270VAC,50Hz/60Hz±1%,local supply or by generator. | ||
| Environmental Temperature: | -10ºC~50ºC | ||
| Relative humidity: | <90% | ||
| Oversize & weight: | 460×360×350mm 28kg | ||
| Communication Port | RS232 | ||
| Printer: | Build-in thermal printer | ||



