• Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment
  • Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment
  • Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment
  • Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment
  • Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment
  • Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment

Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment

After-sales Service: Onsite and Remote Guidance
Warranty: One Year Free Warranty Lifetime Maintenance
Type: Universal Testing Machine
Accuracy Grade: 0.05
Display: LCD
Control: Computer Control
Customization:

Contact Supplier

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
EPBZ-III
Weight
1000-2000Kg
Power Source
AC380V
Test Capacity
5000kVA
Control Mode
Manual/PLC
Test Items
TTR, Dvdf, Resistance, Hipot and Customized
Keywords
Transformer Testing System
Test Console Protection
No Load Test Over-Current Protection Power Frequen
Key Words
Transformer Testing Equipment
Temperature Rise Test
Regulator and Ohmmeter with Tempera Rise Function
Test Object
Distribution Transformers Power Transformers
Protection
No Load Test Over-Current Protection
Protection1
Power Frequency Over-Current Protection.
Protection2
Zero Start Interlock with Auto Return of Regulator
Protection3
Separate Ground Fault Safety Circuit.
Protection4
External Interlock Provision.
Protection5
Emergency Stop Mushroom Button.
Protection6
Alarm Sound & Light During Test.
Transport Package
Plywood Cases
Specification
10+m3
Trademark
EP Hipot Electric
Origin
Wuhan, China
HS Code
8504349000
Production Capacity
100/Year

Product Description

Transformer Test Bench Open Circuit  (OC Test) No Load Losses Test Equipment

Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment
General Information: 
EPBZ series Transformer Test Bench is applied for ex-work and maintenance detecting on various transformers. It's widely used in the fields of power supply and distribution, power transformer manufacturer, transformer maintenance center, industry and mining enterprises.

Features
  • Applied for different voltage degree transformers, reactors and HV switchgears.
  • Fully PLC controlling and measurement, integrated primary wire connection circuit displaying, measuring, control tracing, analysis processing, report storing, printing and protecting into the testing system.
  • All the test data calculation was operated by IPC, the test results and measuring data are displayed in screen directly which highly improved the precision and efficiency.
  • The test system could be customized to bench type, microcomputer type or any at user's option to be suitable for your test site.
  • All test results are corrected according to the requirement of IEC60076 or ANSI C57.


Test Items:
Routine tests:
  1. Transformer oil testing (including acidity, dewpoint, flashpoint, breakdown, capacitance &tan delta, dissolved gas analysis)
  2. Transformer insulation resistance testing
  3. Transformer winding resistance testing
  4. Transformer turns ratio testing
  5. Transformer load/no-load current & loss testing
  6. Transformer capacitance & tan delta testing
  7. Transformer short circuit impedance & load loss testing
  8. Transformer power frequency withstand voltage testing
  9. Transformer induced AC withstand voltage testing (including 110kV transformer partial discharge testing)
  10. Impulse voltage testing (including full wave, chopping wave testing)

Type tests:
  1. Temperature rising testing

Special tests:
  1. Zero-sequence impedance testing
  2. No load current harmonic testing

Function features:
  1. 3 phase 4 wires power supply controlling.
  2. Regulator supply controlling.
  3. Regulator voltage controlling.
  4. CT/PT shifting controlling.
  5. Test voltage/current monitoring for each test item.
  6. Function switching for each test item.
  7. Inductive motor start, stop, voltage increase/decrease, auto timing.
  8. Panel pushbuttons, PC mouse two control modes.
  9. PLC software operating and save test results automatically.
Test console protection:
  1. No load test over-current protection
  2. Power frequency over-current protection.
  3. Zero start interlock with auto return of regulator to zero position.
  4. Separate ground fault safety circuit.
  5. External interlock provision.
  6. Emergency stop mushroom button.
  7. 3 phase 4 wires main power supply.  
  8. Alarm sound & light during test.
Testing equipment including:
1 Transformer Test Bench 7 DC winding resistance tester
2 Inductive regulator 8 Transformer turns ratio tester
3 Motor Generator sets (DVDF) 9 Insulation resistance meter
4 Intermediate transformer (voltage boosting transformer if LV is over 400V) 10 Power frequency withstand voltage test set
5 Sampling cabinet (HV/LV CT/PT cabinet, primary circuits cabinet) 11 Temperature Tester
6 Power analyzer 12 Partial discharge system (PDF detector, coupling capacitor etc.)

Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment
Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment
Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment
Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment
Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment
More details on EPBZ series Transoformer Test System please contact EP Hipot Electric, we have professional tech team to design correctly designed products and systems.

Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment
Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment
Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment
Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment
Transformer Test Bench Open Circuit (OC Test) No Load Losses Test Equipment

Send your message to this supplier

*From:
*To:
avatar Mrs. Ying Ying
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now