• 60kv Automatic Insulation Oil Bdv Tester Transformer Oil Breakdown Voltage Test Kit Oil Testing & Measuring Equipments
  • 60kv Automatic Insulation Oil Bdv Tester Transformer Oil Breakdown Voltage Test Kit Oil Testing & Measuring Equipments
  • 60kv Automatic Insulation Oil Bdv Tester Transformer Oil Breakdown Voltage Test Kit Oil Testing & Measuring Equipments
  • 60kv Automatic Insulation Oil Bdv Tester Transformer Oil Breakdown Voltage Test Kit Oil Testing & Measuring Equipments

60kv Automatic Insulation Oil Bdv Tester Transformer Oil Breakdown Voltage Test Kit Oil Testing & Measuring Equipments

Type: Strength Testing Machine
Display: LCD
Control: Computer Control
Weight: 26kg
Power Source: 220V or 120V at Customized
Keywords: Insulating Oil Breakdown Bdv Tester
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
EPOT Series
Power Supply
AC 220V 50 Hz
Test Voltage
AC 0-60kv (100kv/80kv at Option)
Voltage Boosting Rate
2.0 Kv/S, 3.0 Kv/S(Selectable)
Error
0.2kv/S
Power Distortion
Less 1%
Electrodes Gap
2.5mm
Standing Time
The Default Value Is 15 Min
Interval Time
The Default Value Is 5 Min
Stirring Time
The Default Value Is 10 S
Boosting Voltage
The Default Value Is 100 Kv
Power Consumption
300va
Environmental Temperature
0-35c
Relative Humidity
Less Than 75%Rh
Volume
410 * 390 *380mm
Transport Package
Plywood Case with Foam & Waterproof Plastics
Specification
CE/ISO/IEC
Trademark
EP Hipot Electric
Origin
Wuhan, China
HS Code
9030899090
Production Capacity
1000/Year

Product Description

EPOT-60kV
Insulation Oil Tester (Single Vessel)

General Information:

Keywords: Oil Dielectric Strength Tester
Oil Breakdown Tester  
Transformer Oil Dielectric Strength Tester

EPOT series insulating oil dielectric strength tester is also known as oil breakdown voltage tester or oil BDV tester. Break down voltage is measured by observing at what voltage, sparking string between two electrodes immersed in the oil, separated by specific gap.

EPOT series conforms to international standard IEC-156, can be used for power frequency dielectric break down test on the transformer oil, capacitor oil, electric device, insulation tool, electric manufacturer and etc. It's widely used in the fields of power system, petroleum, chemical industry, railway station, power station, electric manufacturer and etc.


Features:

 
  • Self detecting function. The regulator could return to zero start automatically.
  • Controlled a large capacity single chip microcomputer, which is stable and reliable.
  • The wide range watchdog circuit is set in the tester to prevent the crash.
  • The oil vessel is made of special glass by one-time casting to prevent the occurrence of oil leakage and interference.
  • The unique high-voltage sampling design allows the test value to enter the A / D converter directly, avoids the error caused in the analog circuit, and makes the measurement result more accurate
  • Full protection functions including over-current, over-voltage, short circuit to ensure the safety of operators. And has strong anti-interference ability and good electromagnetic compatibility
  • Build-in printer.
  • Automatic magnetic bar stir, to eliminate uneven and bubble of oil.
  • 100 test data storage, can display the ambient temperature and humidity.
  • Portable structure, easy to move, convenient for use indoor and outdoor.

Specification:
 
Test voltage: AC 0~60kV (100kV/80kV at option)
Voltage boosting rate:  2.0 kV/s,3.0 kV/s(selectable)
Error 0.2kV/s
Power distortion: <1%
Electrodes Gap: 2.5mm
Volume: 410×390×380mm
Weight: 26kg
Environmental temperature: 0-35ºC
Relative humidity: ≤75%RH
Working power AC 220V ± 20%
Power Frequency 50 Hz ± 5 Hz
Power consumption: 300VA
Standing time The default value is 15 min, and the optional range is 1-15 min (increment step is 1 min).
Interval time
 
The default value is 5 min, and the optional range is 1-10 min (increment step is 1 min).
Stirring time: The default value is 10 s, the optional range is 5-90 s (increment step is 5 s)
Boosting voltage: The default value is 60 kV, and the optional range is 10-60 kV (increment step is 10kV).
Testing time: The default value is 6 times, and the optional range is 1-6 times (increment step is 1 time)

More details please contact EPHipot Electric, we have professional tech team to design correctly designed products and systems.

60kv Automatic Insulation Oil Bdv Tester Transformer Oil Breakdown Voltage Test Kit Oil Testing &amp; Measuring Equipments
60kv Automatic Insulation Oil Bdv Tester Transformer Oil Breakdown Voltage Test Kit Oil Testing &amp; Measuring Equipments



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now