Product Highlights

  • Portable and Lightweight Design: Weighs less than 22kg, making it highly portable for convenient field testing.
  • Comprehensive CT/PT Analysis: Supports full function testing for CT and PT including excitation, ratio, and polarity tests.
  • High Precision Measurement: Excitation accuracy is less than 0.5%, ensuring reliable and precise test results.
  • Intelligent Data Management: Stores 3000 sets of data with power failure protection and supports USB transfer to PC.
  • Automatic Curve Calculation: Automatically calculates CT/PT inflection points and 5% and 10% error curves.
  • Customizable Power Source: Power source can be customized to 220V or 120V to meet different regional standards.
  • Instant On-Site Printing: Features a fast printer that directly prints test results on site for immediate records.
  • User-Friendly Interface: Equipped with a large LCD screen and graphical interface with intelligent operation prompts.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III

CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III pictures & photos
CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III pictures & photos
CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III pictures & photos
CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III pictures & photos
CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III pictures & photos
CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III pictures & photos
CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
  • CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
  • CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
    CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
  • CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
    CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
  • CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
    CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
  • CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
    CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
  • CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
    CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
  • CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
    CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III

Find Similar Products

Product Description

EPCP-III
CT/PT Analyzer (Full Functions)

General Information:
EPCP-III is portable analyzer designed for analyzing current transformers and voltage transformers of protection or measurement use, which is suitable for laboratory and on-site test.

Features:
  • Support detection of CT and PT
  • No need to connect other auxiliary equipment, can complete all test items, and complete the excitation and transformation ratio polarity test at the same time in one test.
  • Fast printer, which can print test results directly on site.
  • Easy to operate, with intelligent prompts, making it easier for users to operate.
  • Large screen LCD, graphical display interface.
  • Automatically give CT/PT (excitation) inflection point value according to regulations.
  • Automatically give 5% and 10% error curves.
  • 3000 sets of test data can be saved, which will not be lost after power failure.
  • Support U disk transfer data, can be read through a standard PC, and generate WORD report.
  • Small and light weight ≤22kg, very conducive to field testing.
 
Main Test Functions:

1. Function Table
 
I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Excitation Characteristic Test 1. Excitation Characteristic Test
2. Auto Calculation of Knee Point Value 2. Auto Calculation of Knee Point Value
3. Auto 5% and 10% error curves, can measure ALF 3. Transformer Ratio Test
4. Transformer Ratio Test 3. Polarity
5. Polarity 4. Ratio difference measurement
6. Ratio difference measurement 5. Phase (angle difference) measurement
7. Phase (angle difference) measurement 6. Withstand Test of Power Frequency Alternating Current
8. Primary Current Injecting 7. Actual Secondary Load Test
9. Withstand Test of Power Frequency Alternating Current 8. Secondary Winding Test
10. Secondary Load Test  
11. Secondary Winding Test  
12. Measuring the volt-ampere characteristics of medium and low voltage CTs and zero sequence CTs  
13. Measure GIS, casing CT  
14. Comprehensive test, complete excitation and transformation ratio polarity at the same time in one test  

2. Technical Parameter Table
 
Operational Power Supply: AC220V±10%, 50Hz
Single Machine Output: 0~2500Vrms, 5kVA (maximum setting value 20A)
Primary Current Output: 0~1000A
Excitation accuracy ≤0.5% (0.2%*reading+0.3%*range)
Secondary winding
Resistance measurement
Range 0.1~300Ω
Accuracy ≤0.5% (0.2%*reading+0.3%*range)
Secondary real
Load measurement
Range 5~500VA
Accuracy ≤0.5% (0.2%*reading+0.3%*range) ±0.1VA
Phase measurement
(Angle difference)
Accuracy 4min
Resolution 0.1min
CT ratio measurement range Range ≤25000A/5A(5000A/1A)
Accuracy ≤0.5%
PT ratio measurement range Range ≤500KV
Accuracy ≤0.5%
Operating Temperature: -10ºC~+40ºC
Relative Humidity:   <90RH%
Altitude: ≤1000m
Overall Dimension (Length × Width × Height): 410mm * 260mm * 340(mm)
Weight: ≤22 kg
More details about CTPT Analyser EPCP-III please contact EPHipot Electric, we have professional tech team to design correctly designed products and systems.

CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III


 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR259312". Items marked "verified" are certified.

Watch Video
Watch Video
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building 3, Liandong U Valley, Xingsan Road, Hannan District, 430000, Wuhan, Hubei, China
verified Registered Capital
1,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port; Ningbo Port; Guangzhou Port; Shenzhen Port
verified Minimum Order Quantity
1 Set

Our Production Capability & Technical Expertise

Main Products
Transformer Test Equipment, Circuit Breaker Testing Equipment, High Voltage Test System, CT PT Testing and Calibrating, High Voltage Insulation Testing, DC System and Battery Testing, Cable Faults, Test and Diagnostics, Arrester and Insulator Testing
verified Production Lines
3
verified Production Machines
Assembling Line, Testing Line, Winding Line
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instruction but no written records
verified Customization Options
Customization from Designs, Full Customization, Flexible customization, Minor Customization, Customization from Samples
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified Traceability of Raw Materials
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2017-05-18
verified Export Year
8 Years
verified Main Markets
South America, Europe, Australia
verified Repeat Buyers Choice
80%~100%
verified New Products Launched in Last year
Yes

FAQ

What is the maximum output capacity of the EPCP-III?
The single machine output is 0-2500Vrms, 5kVA, with a maximum setting value of 20A.
Can this device test both CT and PT simultaneously?
Yes, it can complete excitation and transformation ratio polarity tests for both CT and PT in one test.
How much data can the device store?
It can save 3000 sets of test data, which will not be lost even after a power failure.
Is the device suitable for field testing?
Yes, it is small and lightweight (less than 22kg), making it very conducive to field testing.
What is the accuracy of the excitation characteristic test?
The excitation accuracy is less than 0.5%, calculated as 0.2%*Reading + 0.3%*Range.
Does the device support automatic calculation of error curves?
Yes, it automatically provides 5% and 10% error curves and calculates the knee point value.
What are the operating temperature and humidity conditions?
The operating temperature is -10 to +40 degrees Celsius, and relative humidity is less than 90% RH.
Can I customize the power source voltage?
Yes, the power source can be customized to either 220V or 120V.