General Information: EPCR-4000 Power Quality Analyzer is specially designed for field test of three phases, multi-functional and intelligent, concise man-machine opera-tion. It is easy to use, large LCD screen display, high resolution, interface in English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current volt-age, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, trans-former K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc. Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data. In the current power applications, more and more large power equipment, power grid fault have become more and more complex, with development of the industry, it put forward high request more and more to quality that electric energy. We provide this power quality analyzer for that, which you can troubleshoot of complex power system more quickly and accurate, and monitoring and maintenance of power quality parameters more com-prehensive and systemic. EPCR-4000 Power quality analyzer adopt DSP + ARM double processor architecture, DSP is use for data collection and the processing of algorithm, the ARM is use for the communication protocol and the man-machine interface processing. Analog signal acquisition is by 2 pieces ADC Chip of ADI company. Resolution for ADC Chip is 16 bit and it is 4 channel synchronous sampling. The highest sampling rate can reach 1 MSPS, to ensure the accuracy of the channel and the information integrity, and wouldn't miss any transient changes in the grid, can more ac-curate to detect the transient waveform rising and dropping drastically, and waveform instantaneous interrupt; DSP working frequency is over 200 MHZ, to be able to timely monitoring of the power grid and dynamically ad-just the sampling frequency to realize synchronization of power frequency and sampling frequency; Using a 5.6 -inch LCD color screen display, a resolution of 640 dots x 480 dots, with different display color difference be-tween the parameters of phase, waveform, vector diagram, harmonic ratio, the user can be more efficient and more intuitive understand the state of power grid parameters. Built-in flash memory can store 60 group of screenshots at the same time, 150 groups of capture transient voltage/current waveform figure, and 12800 groups of alarm list. Starting current detection model can continuously capture starting current waveform for 100 s. Built-in 2G memory card to store the trend curve record, simultaneous recording 20 parameters (can choose according to need) collect data for once every five seconds, trend curve records can be stored for 300 days. Power Quality Analyzer also named: Intelligent Three Phase Power Quality Analyzer, Multifunctional Power Quality Analyzer, which simultaneous with the functions of harmonic Analyzer, phase volt-ampere meter, electric parameter tester. It applies to electricity industry, petrochemical, metallurgy, railway, mining enterprises, scientific research institution, metrological department. Especially suitable for comprehensive analysis and diagnosis on all the voltage, current, power, power, harmonic, phase electric parameters. |
Influence factor | Test item | Base condition | Working condition |
Environment temperature | All parameters | (23±2)°C | -10°C~ 40°C |
Relative humidity | All parameters | 40%~ 60% | <80% |
Phase-to-neutral voltage | All parameters | (100±1%)V | 1.0V~ 1000V |
Phase-to-phase voltage | True RMS phase-to-phase voltage | (200±1%)V | 1.0V~ 2000V |
Current | True RMS current | (5±1%)A | 10mA~ 6000A |
Network frequency | All parameters | 50Hz±0.1Hz | 40Hz~ 70Hz |
Phase shift | Active power and active energy | Cosφ=1 | Cosφ: 0.2~ 1.0 |
Reactive power and reactive energy | Sinφ=1 | Sinφ: 0.2~ 1.0 | |
Harmonic | All parameters | <0.1% | 0.0%~ 100% |
Voltage unbalance | All parameters | <10% | 0.0%~ 100% |
Working voltage of device | All parameters | DC9.8V±0.1V | DC9.5V~ 10.5V |
External electric field, magnetic field |
All parameters | Should be avoided | |
Test position | Measured related parameters of current | Tested wire at the center of clamp. |
Power supply | Rechargeable lithium-ion battery packs 9.6V, backup charger. |
Battery indicator | Battery symbol shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute. |
Power consumption | Current consumption of normal test 490 mA, continuous working for 10 hours. |
Display mode | LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm. |
Size of clamp | FR008 small sharp current clamp: 8mm×15mm; FR020 circle current clamp: 20mm×20mm; FR050 circle current clamp: 50mm×50mm. FR300R Flexible Coil Current Sensor (with Integrator) : Ф300mm |
Instrument dimensions | L×W×H: 277.2mm × 227.5mm × 153mm. |
Number of channels | 4U/4I. |
Phase-to phase voltage | 1.0V~2000V. |
Phase-to-neutral voltage | 1.0V~1000V. |
Current | EPCR480 current clamp: 10mA~10.0A; EPCR420 current clamp: 0.10A~100A; (option) EPCR450 current clamp: 1.0A~1000A; (option) EPCR600R Flexible Coil Current Sensor (with Integrator) : 10A ~ 6000A (option) |
Frequency | 40Hz~70Hz. |
Parameters of electricity | W, VA, Var, PF, DPF, cosφ, tanφ. |
Energy parameters | Wh, Varh, Vah. |
Harmonic | Order 0~50. |
Total harmonic distortion | Order 0~50, each phase. |
Expert mode | Yes. |
Number of Transient records | 150 sets. |
Voltage flicker | Yes. |
Starting current mode | Yes, 100 seconds. |
3 phases unbalance | Yes. |
Record | 300 days(simultaneous recording 20 parameters, record one point every 5 seconds). |
Min/Max recorded value | Measurement of maximum and minimum values over a period of time. |
Alarm | 40 different types of parameter selections, 12,800 sets alarm logs. |
Peak | Yes. |
Phasor diagram display | Automatically. |
Capacity of snapshots | 60. |
Menu language | English/Chinese. |
Communication | USB. |
Automatic switching off | When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off. |
In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute. | |
Backlight function | Yes, suitable for use at night and dark place. |
Weight | Host: 1.6kg (with battery). |
FR008 small sharp current clamp: 168g×4; | |
FR020 circle current clamp: 252g×4; | |
FR050 circle current clamp: 463g×4; | |
FR300R Flexible Coil Current Sensor (with Integrator) : 280g×4; | |
Test wires and power adapter: 800g; | |
Total weight: about 10.8kg (with packaging). | |
Length of voltage test wire | 3m. |
Length of current sensor wire | 2m. |
Working temperature and humidity | -10°C~40°C; below 80%Rh. |
Storage temperature and humidity | -10°C~60°C; below 70%Rh. |
Input impedance | Input impedance of test voltage: 1MΩ. |
Withstand voltage | Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell. |
Insulation | Between instrument wiring and shell ≥10MΩ. |
Structure | Double insulation, with insulation vibration-proof sheath. |
Safely rules | IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2. |
Measurement | Range | Display resolution | The maximum error in the range of the reference |
Frequency | 40Hz~ 70Hz | 0.01Hz | ±(0.03)Hz |
True RMS phase-to-neutral voltage | 1.0V~ 1000V | Min resolution 0.1V | ±(0.5%+5dgt) |
True RMS phase-to phase voltage | 1.0V~ 2000V | Min resolution 0.1V | ±(0.5%+5dgt) |
DC voltage | 1.0V~ 1000V | Min resolution 0.1V | ±(1.0%+5dgt) |
True RMS current | 10mA~ 6000A | Min resolution 1mA | ±(0.5%+5dgt) |
Peak of phase-to-neutral voltage | 1.0V~ 1414V | Min resolution 0.1V | ±(1.0%+5dgt) |
Peak of phase-to-phase voltage | 1.0V~ 2828V | Min resolution 0.1V | ±(1.0%+5dgt) |
Current peak | 10mA~ 8484A | Min resolution 1mA | ±(1.0%+5dgt) |
Peak factor | 1.00~ 3.99 | 0.01 | ±(1%+2dgt) |
4.00~ 9.99 | 0.01 | ±(5%+2dgt) | |
Active power | 0.000W~ 9999.9kW | Min resolution 0.001W | ±(1%+3dgt) Cosφ≥0.8 |
±(1.5%+10dgt) 0.2≤Cosφ<0.8 |
|||
Reactive power, inductive or capacitive | 0.000VAR~ 9999.9kVAR |
Min resolution 0.001VAR | ±(1%+3dgt) Sinφ≥0.5 |
±(1.5%+10dgt) 0.2≤Sinφ<0.5 |
|||
Apparent power | 0.000VA~ 9999.9kVA |
Min resolution 0.001VA | ±(1%+3dgt) |
Power factor | -1.000~ 1.000 | 0.001 | ±(1.5%+3dgt) Cosφ≥0.5 |
±(1.5%+10dgt) 0.2≤Cosφ<0.5 |
|||
Active energy | 0.000Wh~ 9999.9MWh | Min resolution 0.001Wh | ±(1%+3dgt) Cosφ≥0.8 |
±(1.5%+10dgt) 0.2≤Cosφ<0.8 |
|||
Reactive energy, inductive or capacitive | 0.000VARh~ 9999.9MVARh |
Min resolution 0.001VARh | ±(1%+3dgt) Sinφ≥0.5 |
±(1.5%+10dgt) 0.2≤Sinφ<0.5 |
|||
Papparent energy | 0.000VAh~ 9999.9MVAh |
Min resolution 0.001VAh | ±(1%+3dgt) |
Phase angle | -179°~ 180° | 1° | ±(2°) |
Tanφ (VA≥50VA) |
-32.76~ 32.76 | Min resolution 0.001 | φ:±(1°) |
Phase shift of power factor (DPF) |
-1.000~ 1.000 | 0.001 | φ:±(1°) |
Harmonic ratio (order 1 to 50) (Vrms>50V) |
0.0%~ 99.9% | 0.1% | ±(1%+5dgt) |
Harmonic angle (Vrms>50V) |
-179°~ 180° | 1° | ±(3°) harmonics of order 1 to 25 |
±(10°) harmonics of order 26 to 50 | |||
Total harmonic ratio (THD or THD-F)≤50 |
0.0%~ 99.9% | 0.1% | ±(1%+5dgt) |
Distortion factor (DF or THD-R)≤50 |
0.0%~ 99.9% | 0.1% | ±(1%+10dgt) |
Transformer K factor | 1.00~ 99.99 | 0.01 | ±(5%) |
3 phases unbalance | 0.0%~ 100% | 0.1% | ±(1%) |
Type of current sensor | True RMS current | Max error of true RMS current | Max error of phase angle |
EPCR480 current clamp | 10mA~ 99mA | ±(1%+3dgt) | ±(1.5°),Arms≥20mA |
100mA~ 10.0A | ±(1%+3dgt) | ±(1°) | |
EPCR420 current clamp | 0.10A~ 0.99A | ±(1%+3dgt) | ±(1.5°) |
1.00A~ 100A | ±(1%+3dgt) | ±(1°) | |
EPCR450 current clamp | 1.0A~ 9.9A | ±(2%+3dgt) | ±(3°) |
10.0A~ 1000A | ±(2%+3dgt) | ±(2°) | |
EPCR600 Flexible Coil Current Sensor (with Integrator) | 10A~199A | ±(1 % + 3dgt) | ±(3°) |
200A~6000A | ±(1 % + 3dgt) | ±(2°) |