Ctpt Analyzer Transient Characteristic Analyzer of Transformer

Product Details
Customization: Available
Type: Universal Testing Machine
Display: LCD
Manufacturer/Factory, Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
>2000 square meters
  • Ctpt Analyzer Transient Characteristic Analyzer of Transformer
  • Ctpt Analyzer Transient Characteristic Analyzer of Transformer
  • Ctpt Analyzer Transient Characteristic Analyzer of Transformer
  • Ctpt Analyzer Transient Characteristic Analyzer of Transformer
  • Ctpt Analyzer Transient Characteristic Analyzer of Transformer
  • Ctpt Analyzer Transient Characteristic Analyzer of Transformer
Find Similar Products

Basic Info.

Model NO.
EPCP-IV
Control
Computer Control
Weight
0-100Kg
Power Source
220V or 120V at Customized
IEC
IEC60044-1, IEC60044-6 CT/PT Standard
Phase Measurement Resolution
0.01min
Secondary Winding Resistance Range
0ohm~300ohm
AC Load Measurement Range
0va~1000va
Output Voltage
0VAC~180VAC
Output Current
0aeff~12aeff(36apeak)
Output Power
0vaeff~800vaeff(1800vapeak)
Test Item
CT: Excitation Characteristic, Turns Ratio, Polari
Input Voltage
185VAC~250VAC
Allowed Input Voltage
85VAC~264VAC
Frequency
50/60Hz
Allowed Frequency
45Hz~65Hz
Input Power
800va
Data Storage
1000 Groups
LCD Screen
5.7′
Transport Package
Plywood Case with Warter Proof Plastic
Specification
360*285*145mm
Trademark
EP Hipot
Origin
Wuhan, China
HS Code
9030820000
Production Capacity
2000/Year

Product Description

EPCP-IV
CT/PT Analyzer (Variable Frequency)

General Information:
EPCP-IV is portable analyzer designed for analyzing current transformers and voltage transformers of protection or measurement use, which is suitable for laboratory and on-site test.

Features:
  • 5.7' LCD screen, display clearly even under sunshine.
  • Rotating photoelectric mouse, easy to operate.
  • Build in printer to print test result automatically after testing completed.
  • Full functions, satisfy all kinds of CT (protection CT, measuring CT, TP) test requirements, such as excitation characteristic test, turn ratio, polarity, secondary winding resistance, secondary burden, ratio error, angular difference etc. Also, it can be used to test excitation characteristic, turn ratio, polarity, secondary winding resistance, ratio error, angular difference etc. all kinds of PT.
  • Auto test CT/PT parameters on knee point voltage/current, 5% and 10% deviation curve measurement, Accuracy limit factor (ALF), safety factor (FS), second time constants (Ts), residual magnetism factor (Kr), saturated and unsaturated inductance.
  • Accurately measure ratio error and angular error. Max. Ratio error ±0.1% is permitted. Max. Angular error ±5min if permitted. It can measure 0.2S class CT and turns ratio range is 1-40000.
  • Complied with IEC60044-1, IEC60044-6 standards of all kinds of CT/PT.
  • Using variable frequency method can deal with60kV CT test when keen point is as high as 60kV.
  • Easy to use. To test CT DC resistance, excitation and polarity only by one button. All CT tests adopt same one connects method except load test.
  • To export test data by U disk.
  • 1000 groups' data storage, data can be saved even power failure.
  • Friendly interface, English graphical interface.
  • Small size and portable, weight less than 10KG.
 
Main Test Functions:
 
Model EPCP-IV
Test Item CT: Excitation characteristic, Turns Ratio, Polarity, Secondary Winding Resistance, secondary load, Ratio test and angular tests.
PT
:Excitation characteristic, Turns Ratio, Polarity,Secondary Winding Resistance.
Power Supply Input Voltage 185Vac~250Vac
Allowed Input Voltage 85Vac~264Vac
Frequency 50/60Hz
Allowed Frequency 45Hz~65Hz
Input Power 800VA
Connector Standard AC socket 60320
CT
Turns Ratio
Accuracy
Turns Ratio 1~2000 0.05% (Typical value)/0.1% (Guarantee value)
Turns Ratio 2000~5000 0.07% (Typical value)/0.2% (Guarantee value)
Turns Ratio 5000~40000 0.1% (Typical value)/0.5% (Guarantee value)
PT
Turns Ratio
Accuracy
Turns Ratio 1~2000 0.05% (Typical value)/0.1% (Guarantee value)
Turns Ratio 2000~5000 0.07% (Typical value)/0.2% (Guarantee value)
Turns Ratio 5000~40000 0.1% (Typical value)/0.5% (Guarantee value)
 
Phase Measurement Resolution 0.01min
Accuracy 2min (Typical value)/5min (Guarantee value)
Secondary Winding Resistance Range ~300Ω
Resolution 1mΩ
Accuracy 0.1% (Typical value)/0.2%±2mΩ (Guarantee value)
AC Load Measurement Range 0VA~1000VA
Resolution 0.01VA
Accuracy 0.1% (Typical value)/0.2%±0.02VA (Guarantee value)
Output Voltage 0Vac~180Vac
Current 0Aeff~12Aeff(36Apeak)
Power 0VAeff~800VAeff(1800VApeak)
Working Condition Operation Temperature -10ºC~+50ºC
Storage Temperature -25ºC~+70ºC
Relative Humidity 5%~95%,No Condensation
Dimension 360×285×145mm3
Weight 8kg (Excluding accessories)

More details about CTPT Analyser EPCP-IV please contact EPHipot Electric, we have professional tech team to design correctly designed products and systems.

Ctpt Analyzer Transient Characteristic Analyzer of Transformer
Ctpt Analyzer Transient Characteristic Analyzer of Transformer


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier