Ep Hipot Electric Gas Chromatography Oil Dga Dissolved Gas Analyzer

Product Details
Customization: Available
After-sales Service: Onsite and Remote Guidance
Warranty: 1or 2 Years Free Warranty Longlife Service
Manufacturer/Factory, Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
>2000 square meters
  • Ep Hipot Electric Gas Chromatography Oil Dga Dissolved Gas Analyzer
  • Ep Hipot Electric Gas Chromatography Oil Dga Dissolved Gas Analyzer
  • Ep Hipot Electric Gas Chromatography Oil Dga Dissolved Gas Analyzer
  • Ep Hipot Electric Gas Chromatography Oil Dga Dissolved Gas Analyzer
  • Ep Hipot Electric Gas Chromatography Oil Dga Dissolved Gas Analyzer
  • Ep Hipot Electric Gas Chromatography Oil Dga Dissolved Gas Analyzer
Find Similar Products

Basic Info.

Model NO.
EPGC-20Smart
Display
LCD Touch Screen
Screen Display
7-Inch Color Touch Screen
Display Accuracy
0.1oc
Oven Lift Rate
Any Stage Platform Program Temperature Rise, up to
Repeatability of Temperature Program
Less Than 1%
(Fid) Maximum Operating Temperature
400 Oc
(Fid) Detection Limit
5*10-12g/S (N-Hexadecane)
(Fid) Baseline Noise
Less 2*10-14A
(Fid) Dynamic Linear Range
10 7
(Tcd) Baseline Noise
Less 10UV
(Tcd) Maximum Use Temperature
300 Oc
(Tcd) Sensitivity
S Value Higher Than 9000mv.Ml/Mg (Benzene)
(Tcd) Baseline Drift
Less 50UV/30min
Chromatographic Column
One for Measuring H2, Co, CO2, One for Measuring C
Special Tools and Consumables
Epgc-Smart
Key Words
Transformer Oil Gas Chromatography Analyser
Transport Package
Plywood Cases
Trademark
EP Hipot Electric
Origin
Wuhan, China
HS Code
9030332000
Production Capacity
1000/Year

Product Description

EP Hipot Electric Gas Chromatography Oil DGA Dissolved Gas Analyzer

General Information:
Transformer Oil Dissolved Gas Analyzer (also called: Transformer Oil Gas Chromatography Analyzer) uses chromatographic method to determine the content of dissolved gas in transformer oil. It is effective for power generation and power supply companies to determine whether there are latent overheating, discharge and other faults in oil-filled power equipment in operation to ensure safe and effective operation of the power grid. means. It is also a necessary means for manufacturers of oil-filled electrical equipment to carry out factory inspections of their equipment.

It is suitable for the determination of the content of the dissolved gas components in the insulating oil of the power system. The full analysis of the content of the 7 gas components dissolved in the insulating oil can be completed with one sample injection. The minimum detection concentration of acetylene is 0.01ppm, and the stabilization time is less than the baseline was stable at 40 minutes.
Composition of detection objects: H2, CO, CO2, CH4, C2H4, C2H6, C2H2.

Reference standard: IEC60599-2015,  IEC60567-2011      

Features:
  • The control panel adopts a 7-inch color touch screen design with intuitive display, rich content and easy operation.
  • The electronic gas circuit control system has higher and more precise control accuracy. It has multiple control modes such as constant current, constant pressure, program pressure and flow rate, which realizes the comprehensive digitization and intelligence of the instrument, and ensures the repeatability and accuracy of the analysis results. sex.
  • The chromatographic process with three detector signals output at the same time has good separation effect and high sensitivity.
  • Intelligent self-diagnosis function, the program can diagnose and protect the circuit itself. When the carrier gas leaks or loses gas, the bridge current will be automatically disconnected, which improves the reliability of the instrument.
  • The instrument has intelligent operating procedures such as power-on self-check, automatic temperature rise, FID ignition and TCD plus bridge flow. After power-on, it can quickly reach a stable state and perform sample analysis without any operation.
  • It can remotely operate the instrument, observe spectra, query data, and remotely calibrate through the network.

Transformer oil and gas composition detection test method
1. Turn on the three gas sources of carrier gas, hydrogen and air in sequence, adjust the output pressure of the three gas sources to normal values (carrier gas 0.4Mpa, hydrogen 0.3Mpa, air 0.4Mpa), ventilate for about ten minutes, and turn on the chromatograph host Under the default intelligent control state, the chromatographic workstation automatically completes the self-checking of the working condition parameters, and the control instrument automatically completes the operations of heating, ignition, and adding bridge flow until it prompts to enter the "analysis state"
 
2. Make a template: Use a 1ml quantitative card to take the inlet phase of the calibration gas and get the map. After processing the map, fill in the calibration gas concentration in the corresponding table, use the normalization method to get the correction factor, after the factor is obtained, change to the oscillation method and save As a template.
 
3. Oil sample treatment: Use a 100ml glass syringe to take 40ml oil sample, pinch the rubber cap to seal, and exhaust the air. Use a 5ml glass syringe to take 5ml of nitrogen gas, seal it with a rubber cap and insert a two-way needle, inject 5ml of nitrogen into the oil sample of a 100ml glass syringe, put the oil sample into the shaker, keep the temperature at 50 degrees, oscillate for 20 minutes, and stand still for 10 minutes Then take it out, use a 5ml glass syringe to draw out the gas, read the volume of the outgassed and record it.
 
4. Oil sample measurement: Use a 1ml quantitative card to extract 1ml of oil and gas, enter it into the chromatograph and click start. After the map is obtained, import the template, process the map, fill in the volume of the extracted gas, temperature, and oil sample volume and calculate the result to obtain the oil and gas concentration.


Specification of gas chromatograph analyzer for transformer oil:
 
Analyzer 7-inch color touch screen display, English switching, intelligent man-machine dialogue
Temperature control: 4ºC~450ºC above room temperature, liquid nitrogen refrigeration: -80ºC-400ºC
Column box temperature control accuracy: ±0.02ºC
Display accuracy: 0.1ºC
Oven lift rate: any stage platform program temperature rise, up to 120ºC/min
 Repeatability of temperature program: 1%
Hydrogen flame detector (FID) Maximum operating temperature 400ºC
Detection limit: 5×10-12g/s (n-hexadecane)
Baseline drift: 1×10-13A/30 min (after the instrument is stable for 2 hours)
Baseline noise: 2×10-14A
Dynamic linear range: 107
Thermal conductivity detector (TCD) Maximum use temperature 300ºC
Sensitivity: S value 9000mv.ml/mg (benzene)
Baseline drift: 50uv/30min
Baseline noise: 10uv
Dynamic range: 105
Chromatographic column For transformer oil, one for measuring H2, CO, CO2, one for measuring CH4, C2H4, C2H6, C2H2, and one for TCD reference column
Ni conversion furnace Convert trace amount of CO CO2 to CH4 and respond in FID
Special tools and consumables For EPGC-SMART

More details on Oil Dissolved Gas Analyzer (also called: Transformer Oil Gas Chromatography Analyzer) , please contact EPHipot Electric, we have professional tech team to design correctly designed products and systems.

Ep Hipot Electric Gas Chromatography Oil Dga Dissolved Gas Analyzer
Ep Hipot Electric Gas Chromatography Oil Dga Dissolved Gas Analyzer
Ep Hipot Electric Gas Chromatography Oil Dga Dissolved Gas Analyzer
Ep Hipot Electric Gas Chromatography Oil Dga Dissolved Gas Analyzer
Ep Hipot Electric Gas Chromatography Oil Dga Dissolved Gas Analyzer
Ep Hipot Electric Gas Chromatography Oil Dga Dissolved Gas Analyzer





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier