Parameters for Oltc Monitoring Test Equipment Transformer on Load Tap Changer Analyzer
Contact Supplier
Product Highlights
- Large Output Current Options: Supports 1.0A, 0.5A, and 0.2A output currents for versatile testing needs.
- Long Battery Life: Built-in large capacity lithium battery allows operation without external power supply.
- Smart APP Control: Connect via Android phone or tablet to control instrument and upload data using special software.
- High Brightness Display: Seven-inch high brightness touch color LCD ensures clear visibility under strong light.
- Extensive Data Storage: Automatically saves up to 500 groups of test data internally for easy reference.
- Comprehensive Protection: Features perfect protection circuit ensuring strong reliability during operation.
- Flexible Customization: Test lead length and power supply voltage can be customized to specific requirements.
Product Attributes
- Customization
- Available
- After-sales Service
- Onsite and Remote Guidance
- Warranty
- 1or 2 Years Free Warranty Longlife Service
- Model NO.
- EPCA
- Max Diameter of Workpiece
- <500mm
- Mass Scope of Workpiece
- <900kg
- Type
- Universal Testing Machine
- Accuracy Grade
- 0.5
- Display
- LCD
- Control
- Computer Control
- Weight
- 0-100Kg
- Power Source
- 220V or 120V at Customized
- Output Current
- 1.0A, 0.5A, 0.2A
- Transition Resistance
- 0.3ohm~20 Ohm (1.0A)
- 5 Ohm~40 Ohm (0.5A)
- 20ohm~100ohm(0.2A)
- Transition Time
- 0~320ms
- Open Circuit Voltage
- 24V
- Measuring Accuracy
- 0.1%
- Sampling Rate
- 20kHz
- Analyzer
- 360 * 290 * 170 (mm)
- Accessories Box
- 360 * 290 * 170 (mm)
- Analyser Weight
- Analyzer: 6kg
- Test Lead Length
- The Standard Length of The Test Line Is 13 Meters
- Ambient Temperature
- - 10~50 Degree
- Ambient Humidity
- Less 85% Rh
- Working Power Supply
- AC220V +- 10%
- Power Frequency
- 50+-1Hz
- Transport Package
- Plywood Case with Foam and Waterproof Plastics
- Trademark
- EP Hipot Electric
- Origin
- Wuhan, China
- HS Code
- 9030820000
- Production Capacity
- 1000/Year
Product Images of Parameters for Oltc Monitoring Test Equipment Transformer on Load Tap Changer Analyzer
Find Similar Products
Product Description
ON LOAD TAP CHANGER ANALYZER EPCA
General Information:
On load tap changer is the only moving part connected with the transformer circuit, so the detection of on load tap changer has attracted more and more attention. In the Code for Handover and Preventive Test of Electric Equipment, it is required to check the action sequence of on load tap changer and measure the switching time. The instrument is mainly used to measure the transition waveform, transition time, transient resistance value and three-phase synchronization of transformer on load tap changer.
Features:
- The instrument has large output current and light weight
- Test Yn, Y, D type transformers, and display the resistance value directly without conversion
- Measurement with or without winding
- The waveform display automatically adjusts the resistance and time value amplitude according to the sampling value
- It has perfect protection circuit and strong reliability
- Seven inch high brightness touch color LCD, clear display under strong light, full touch screen operation
- Built in large capacity lithium battery, no external power supply (optional)
- 500 groups of data can be automatically saved internally
- The instrument can use Android phone or tablet, follow WeChat official account, download special APP, control the instrument through special software, store and upload test data for easy reference
Technical Specifications:
| Output current | 1.0A, 0.5A, 0.2A |
| Measuring range | Transition resistance: 0.3 Ω~20 Ω (1.0A) 5 Ω~40 Ω (0.5A) 20Ω~100Ω(0.2A) |
| Transition time: 0 ~ 320ms | |
| Open circuit voltage | 24V |
| Measuring accuracy | Transition resistance: ± (5% reading ± 0.1 Ω) Transition time: ± (0.1% reading ± 0.2ms) |
| Sampling rate | 20kHz |
| Overall dimensions | Analyzer: 360 * 290 * 170 (mm) Accessories box: 360 * 290 * 170 (mm) |
| Instrument weight | Analyzer: 6KG Accessories box 4.5KG |
| Test lead length | The standard length of the test line is 13 meters, which can be customized |
| Ambient temperature | - 10 ºC~ 50 ºC |
| Ambient humidity | ≤ 85% RH |
| Working power supply | AC220V ± 10% |
| Power frequency | 50 ± 1Hz |
More details on Transformer Load Tap Changer Analyzer (OLTC) EPCA series please contact EPHipot, we have professional tech team to design correctly designed products and systems.
About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR259312". Items marked "" are certified.
Company Profile
EP Hipot Electric Co., Ltd has rich experience of more than 20 years in R& D, manufacturing and marketing of market-leading high voltage test equipment. Passion, knowledge, expertise and technology drive us to help our customers all over the world, to maintain their assets value, improve their reliability, reduce maintenance costs and extend working life of the electrical systems and related apparatus. Our application specialists also perform on site trainings and workshops in order to share our knowledge with customers. We maintain quality control so that you can trust our products and receive expert help in selecting or servicing equipment. We are proud of the work we do to help utilities and electrical contractors keep the lights on and protect critical loads all over the world.
From the date of order placing, we usually need 3-7 working days to manufacturing. Located in Wuhan City, the provincial capital of China, EP Hipot Electric is easy to ship the package by the air or ocean. EP Hipot Electric also can provide OEM service according your customized. We are sincerely looking forward to cooperate with you from all the countries of the whole world.
We understand our customers' requirements and we supply the most advanced solutions for testing their electrical apparatus. Our test equipment is designed and produced according to the most widely adopted international standards. The test sets are crafted one by one, using the best available technology and according to ISA 9001 Quality System. We supply rugged products all over the world and thanks to the network of qualified service centers on all continents we perform after sale service and quick support as well as assistance to our customers.
About Our Factory & Business Background
-
Business Type
- Manufacturer/Factory & Trading Company
- Address
- Building 3, Liandong U Valley, Xingsan Road, Hannan District, 430000, Wuhan, Hubei, China
-
Registered Capital
- 1,000,000 RMB
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment
-
International Commercial Terms(Incoterms)
- FOB, CIF, CFR, EXW
-
Average Lead Time
-
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays -
Nearest Port
- Shanghai Port; Ningbo Port; Guangzhou Port; Shenzhen Port
-
Minimum Order Quantity
- 1 Set
Our Production Capability & Technical Expertise
- Main Products
- Transformer Test Equipment, Circuit Breaker Testing Equipment, High Voltage Test System, CT PT Testing and Calibrating, High Voltage Insulation Testing, DC System and Battery Testing, Cable Faults, Test and Diagnostics, Arrester and Insulator Testing
-
Production Lines
- 3
-
Production Machines
- Assembling Line, Testing Line, Winding Line
-
Inspection Type for Finished Products
- 100% inspection(Visual inspection & Function inspection)
-
Inspection Method for Finished Products
- Have instruction but no written records
-
Customization Options
- Customization from Designs, Full Customization, Flexible customization, Minor Customization, Customization from Samples
-
ODM Service Available
- Yes
-
OEM Service Available
- Yes
-
Traceability of Raw Materials
- Yes
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2017-05-18
-
Export Year
- 8 Years
-
Main Markets
- South America, Europe, Australia
-
Repeat Buyers Choice
- 80%~100%
-
New Products Launched in Last year
- Yes
FAQ
- What is the warranty period for this equipment?
- We provide a 1 or 2-year free warranty with long-life service and onsite or remote guidance.
- Can the test lead length be customized?
- Yes, the standard test line length is 13 meters, but it can be customized according to your needs.
- Does the analyzer require an external power supply?
- No, it features a built-in large capacity lithium battery for operation without external power, though an external supply is optional.
- What is the maximum workpiece diameter supported?
- The equipment supports a maximum workpiece diameter of less than 500mm and a mass scope of less than 900kg.
- What are the available output current levels?
- The analyzer offers three output current levels: 1.0A, 0.5A, and 0.2A.
- What are the minimum order quantity and payment terms?
- The minimum order quantity is 1 set. Payment terms include LC, T/T, D/P, PayPal, Western Union, and small-amount payments.
- How long does it take to deliver the product?
- The average lead time is within 15 workdays, regardless of whether it is peak or off-peak season.
Send your message to this supplier
People who viewed this also viewed
-
US$2,990.00-8,970.00 / Piece
-
US$1,290.00-4,980.00 / Set
-
US$2,200.00-5,900.00 / Set
-
US$3,900.00-59,900.00 / Set
-
US$200.00-2,000.00 / Set
-
US$3,968.00-92,158.00 / Set
-
US$496.00-1,998.00 / Piece
-
US$1,190.00-2,280.00 / Piece
-
US$1,000.00-2,280.00 / Piece
-
US$2,200.00-5,900.00 / Set
Find Similar Products By Category
- Supplier Homepage
- Products
- Transformer testing
- Transformer load tap changer tester
- Parameters for Oltc Monitoring Test Equipment Transformer on Load Tap Changer Analyzer
Related Categories
Hot Searches
- Electronic Load Factories
- Lab Equipment Factories
- Testing Machine Factories
- Function Testing Factories
- Test Analyzer
- Analyzer Test Equipment
- Analyzer Tester
- Transformer Testing Set
- Transformer Tester
- Oltc Analyzer Bulkbuy