  • Large Output Current Options: Supports 1.0A, 0.5A, and 0.2A output currents for versatile testing needs.
  • Long Battery Life: Built-in large capacity lithium battery allows operation without external power supply.
  • Smart APP Control: Connect via Android phone or tablet to control instrument and upload data using special software.
  • High Brightness Display: Seven-inch high brightness touch color LCD ensures clear visibility under strong light.
  • Extensive Data Storage: Automatically saves up to 500 groups of test data internally for easy reference.
  • Comprehensive Protection: Features perfect protection circuit ensuring strong reliability during operation.
  • Flexible Customization: Test lead length and power supply voltage can be customized to specific requirements.

Product Images of Parameters for Oltc Monitoring Test Equipment Transformer on Load Tap Changer Analyzer

Parameters for Oltc Monitoring Test Equipment Transformer on Load Tap Changer Analyzer pictures & photos
Parameters for Oltc Monitoring Test Equipment Transformer on Load Tap Changer Analyzer

Find Similar Products

Product Description

EPCA Transformer OLTC On Load Tap Changer Tester OLTC Analyzer

ON LOAD TAP CHANGER ANALYZER EPCA 
General Information:
On load tap changer is the only moving part connected with the transformer circuit, so the detection of on load tap changer has attracted more and more attention. In the Code for Handover and Preventive Test of Electric Equipment, it is required to check the action sequence of on load tap changer and measure the switching time. The instrument is mainly used to measure the transition waveform, transition time, transient resistance value and three-phase synchronization of transformer on load tap changer.


Features:
  • The instrument has large output current and light weight
  • Test Yn, Y, D type transformers, and display the resistance value directly without conversion
  • Measurement with or without winding
  • The waveform display automatically adjusts the resistance and time value amplitude according to the sampling value
  • It has perfect protection circuit and strong reliability
  • Seven inch high brightness touch color LCD, clear display under strong light, full touch screen operation
  • Built in large capacity lithium battery, no external power supply (optional)
  • 500 groups of data can be automatically saved internally
  • The instrument can use Android phone or tablet, follow WeChat official account, download special APP, control the instrument through special software, store and upload test data for easy reference

Technical Specifications:
Output current 1.0A, 0.5A, 0.2A
Measuring range Transition resistance:
0.3 Ω~20 Ω (1.0A)
5 Ω~40 Ω (0.5A)
20Ω~100Ω(0.2A)
Transition time: 0 ~ 320ms
Open circuit voltage 24V
Measuring accuracy Transition resistance: ± (5% reading ± 0.1 Ω)
Transition time: ± (0.1% reading ± 0.2ms)
Sampling rate 20kHz
Overall dimensions Analyzer: 360 * 290 * 170 (mm)
Accessories box: 360 * 290 * 170 (mm)
Instrument weight Analyzer: 6KG
Accessories box 4.5KG
Test lead length The standard length of the test line is 13 meters, which can be customized
Ambient temperature - 10 ºC~ 50 ºC
Ambient humidity 85% RH
Working power supply AC220V ± 10%
Power frequency 50 ± 1Hz

More details on Transformer Load Tap Changer Analyzer (OLTC) EPCA series please contact EPHipot, we have professional tech team to design correctly designed products and systems.


Parameters for Oltc Monitoring Test Equipment Transformer on Load Tap Changer Analyzer
Parameters for Oltc Monitoring Test Equipment Transformer on Load Tap Changer Analyzer
Parameters for Oltc Monitoring Test Equipment Transformer on Load Tap Changer Analyzer
Parameters for Oltc Monitoring Test Equipment Transformer on Load Tap Changer Analyzer
Parameters for Oltc Monitoring Test Equipment Transformer on Load Tap Changer Analyzer
Parameters for Oltc Monitoring Test Equipment Transformer on Load Tap Changer Analyzer
Parameters for Oltc Monitoring Test Equipment Transformer on Load Tap Changer Analyzer





 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR259312". Items marked "verified" are certified.

Watch Video
Watch Video
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building 3, Liandong U Valley, Xingsan Road, Hannan District, 430000, Wuhan, Hubei, China
verified Registered Capital
1,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port; Ningbo Port; Guangzhou Port; Shenzhen Port
verified Minimum Order Quantity
1 Set

Our Production Capability & Technical Expertise

Main Products
Transformer Test Equipment, Circuit Breaker Testing Equipment, High Voltage Test System, CT PT Testing and Calibrating, High Voltage Insulation Testing, DC System and Battery Testing, Cable Faults, Test and Diagnostics, Arrester and Insulator Testing
verified Production Lines
3
verified Production Machines
Assembling Line, Testing Line, Winding Line
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instruction but no written records
verified Customization Options
Customization from Designs, Full Customization, Flexible customization, Minor Customization, Customization from Samples
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified Traceability of Raw Materials
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2017-05-18
verified Export Year
8 Years
verified Main Markets
South America, Europe, Australia
verified Repeat Buyers Choice
80%~100%
verified New Products Launched in Last year
Yes

FAQ

What is the warranty period for this equipment?
We provide a 1 or 2-year free warranty with long-life service and onsite or remote guidance.
Can the test lead length be customized?
Yes, the standard test line length is 13 meters, but it can be customized according to your needs.
Does the analyzer require an external power supply?
No, it features a built-in large capacity lithium battery for operation without external power, though an external supply is optional.
What is the maximum workpiece diameter supported?
The equipment supports a maximum workpiece diameter of less than 500mm and a mass scope of less than 900kg.
What are the available output current levels?
The analyzer offers three output current levels: 1.0A, 0.5A, and 0.2A.
What are the minimum order quantity and payment terms?
The minimum order quantity is 1 set. Payment terms include LC, T/T, D/P, PayPal, Western Union, and small-amount payments.
How long does it take to deliver the product?
The average lead time is within 15 workdays, regardless of whether it is peak or off-peak season.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now