EPBTC
Transformer Power Analyzer
General Information:
General Information:
EPBTC Transformer Load / No-load Tester is a high-precision instrument used for measuring characteristic parameters such as transformer capacity, no-load, load, and energy efficiency level. EPBTC is a multifunctional measuring instrument, equivalent to the usual two testing instruments: transformer capacity tester and transformer characteristic parameter tester. It can accurately measure a series of power frequency parameters such as capacity, energy efficiency level, type, no-load current, no-load loss, short-circuit (load) loss, impedance voltage, etc. of various transformers. (Also called Transformer Power Analyzer)
Also called: Transformer Iron & Copper Loss Tester, Transformer load/no-load Tester, Transformer Capacitance and Load No Load Tester
Standard: IEC270
Features
- It can accurately measure the capacity of various distribution transformers, which is convenient and accurate.
- It can measure the no-load current, no-load loss, short-circuit voltage and short-circuit (load) loss of the transformer.
- The tester automatically switches the range within the instrument, allowing the measurement voltage and current range to be wide and the wiring to be simple..
- When doing the no-load and load test of the three-phase transformer, the instrument can automatically judge whether the wiring is correct, and display a vector diagram of the three-phase voltage and current.
- One can measure the load test below 1000kVA distribution transformer at full current, measuring the load test in 1/3 rated current can be completed under 3150kVA distribution transformers (in the 1/3 of the rated current under the tester can be converted to the load loss parameters under the rated current).
- All test results are automatically corrected. The tester can carry out many kinds of correction, such as waveform correction, temperature correction, non-rated voltage correction, non-rated current correction and so on.
- 320 * 240 large screen, high brightness LCD display, touch button makes the operation more convenient, wide temperature LCD with brightness adjustment, can adapt to the winter and summer season.
- The tester can be preset by the user 40 sets of sample parameters, and these parameters can be deleted at any time as required, and the use is very convenient.
- With real-time electronic clock, automatically record the date and time of the test, which is conducive to the preservation and management of the test results.
- Panel type thermal printer, can quickly print the results of the field test.
- Data (test set, measurement results, test time, etc.) with the power down storage and browsing capabilities, can store 500 sets of test results, and the computer can send data online.
- Allow external voltage transformer and current transformer to expand the range measurement, can measure any parameters of the subject matter.
Technical Specifications:
Test Items |
RMS of three phase voltage: Uab, Ubc, Uca. Average value of three phase AC voltage: Uab, Ubc, Uca. RMS of three phase current: Ia, Ib, Ic. Percentage of No-load loss and No-load current: Po, Io%. Load loss, impedance voltage percentage, short circuit impedance: Pt, ekt, Zt. Load loss, impedance voltage percentage and short circuit impedance at any specified temperature. Transformer actual capacity and judged capacity. |
External power supply: |
220VAC±10%, 45Hz~55Hz |
AC voltage |
Range |
10~650V |
Resolving power |
0.001V |
Accuracy |
0.2%±0.001V |
AC Current |
Range |
0.5~60A |
Resolving power |
0.001A |
Accuracy |
0.2%±0.001A |
Frequency |
Range |
45Hz~65Hz |
Resolving power |
0.001Hz |
Accuracy |
0.2%±0.001Hz |
Power |
Range |
0~39kW |
Resolving power |
0.001kW |
Accuracy |
<±0.5%(CosΦ>0.1), ±1.0%(0.02<CosΦ<0.1) |
Environment condition |
Operating temperature |
-10ºC~+50ºC |
Storage temperature |
-25ºC~+70ºC |
Humidity |
5%~95%, No condensation |
Size |
400×300×220mm |
Weight |
≈8kg (Excluding test wires) |
Measurement range
Capacity |
10kV Oil-immersed, dry type transformer: 30kVA ~ 2500kVA;
35kV Oil-immersed transformer: 50kVA ~ 31500kVA;
20kV Dry type transformer: 50kVA ~ 2500kVA;
35kV Dry type transformer: 50kVA~2000kVA; |
Voltage |
0 ~ 450V (phase voltage),
0 ~ 800V (line voltage), auto switching range |
Current |
0 ~ 100A, auto switching range |
Frequency |
45Hz~65Hz |
Test accuracy
Voltage |
20~100V, ±0.2%FS; 100~450V, ±(0.2%+3 digit); |
Current |
0.5~10A, ±0.2%FS; 10~100A, ±(0.2%+3 digit); |
Power |
±0.5% (CosΦ>0.1), ±1.0% (0.02<CosΦ<0.1); |
More details please contact EP Hipot Electric, we have professional tech team to design correctly designed products and systems.