Automatic Hig Voltage High Current Cable Tan Delta and Capacitance Dielectric Loss & Dissipation Factor Tester 10A 1000kv Cable C&Df Tester

Product Details
Customization: Available
After-sales Service: Remote Guidance
Warranty: 2 Years Free Warranty Longlife Service
Manufacturer/Factory, Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
>2000 square meters
  • Automatic Hig Voltage High Current Cable Tan Delta and Capacitance Dielectric Loss & Dissipation Factor Tester 10A 1000kv Cable C&Df Tester
  • Automatic Hig Voltage High Current Cable Tan Delta and Capacitance Dielectric Loss & Dissipation Factor Tester 10A 1000kv Cable C&Df Tester
Find Similar Products

Basic Info.

Model NO.
EPJS-XP
Maxcapacity
<1000KN
Accuracy Grade
1
Display
LCD
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Current Range of Test Object
10ua-10A
Voltage Range of Test Object
0.5kv-1000kv
Capacitance Range
Unlimited, Resolution 0.001PF, Default 10PF-10UF
Capacitor Temperature
Less Than 3 * 10-5degree
Coefficient Pressure Coefficient
Less Than 3 * 10-3MPa
Installation and Operation Altitude of T
Shall Not Exceed 1000m
The Capacitor Is Filled with
Sf6 Gas
Applied
Cable, Transformer and etc.
Built in
Large Capacity Lithium Battery
Charger Power Supply
180-270VAC, 50Hz / 60Hz
Key Word
Tan Delta Tester
Test Item
Cable Tan Delta
U-Disk
Have
USB
Have
Portable
Yes
Transport Package
Plywood Case with Waterproof Plastic
Specification
460*360*350mm
Trademark
EP Hipot
Origin
Wuhan, China
HS Code
9031809090
Production Capacity
500/Year

Product Description

EPJS-XP(Cable)
Cable Capacitance & Tan Delta Tester


General Information:
EPJS-XP is a new generation, fully automatic on-site measure dielectric loss(tgδ)and the capacitance (Cx) of electric equipment. It's suitable for testing on cable, transformer, insulating bush, capacitor, CT/PT, MOA and etc.

Features:
1. Digital waveform analysis, bridge self-calibration and other technologies are used to achieve high-precision dielectric loss measurement with high-precision three terminal standard capacitor. The input resistance of all ranges of the instrument is less than 2 Ω, so the influence of additional capacitance of measuring cable is eliminated.

2. The scheme of combining high-voltage capacitor and dielectric loss bridge is adopted to simplify the process of wiring debugging. And ensure the safety of the bridge test.

3. Be able to use the high-voltage power supply provided by series resonance without fixed frequency. The built-in series and parallel dielectric loss measurement models are convenient for instrument verification.

4. With standard current input channel, external standard capacitor can be used for dielectric loss test. The dielectric loss bridge can also be calibrated in the laboratory.

5. Wireless communication is adopted between the controller and the high-voltage bridge, with long transmission distance, safety and reliability, and convenient control.

6. The controller adopts 7-inch color screen display, touch screen input and U-disk interface.

7. The controller data stor age is unlimited. You can select a time period to view the stored data. Data can be exported through U disk for computer data analysis.

8. The high-voltage bridge and controller have built-in rechargeable batteries, which do not need power supply during operation.


Specifications:
 
Accuracy:
 
Cx: ± (reading × 1% + 0.01pf)
Tgδ: ± (reading × 1% + 0.00040)
Capacitance range: Unlimited, resolution 0.001pf, default 10pF-10uF.
tgδ δ range: unlimited, resolution 0.001%.
Current range of test object: 10uA ~ 10A.
Voltage range of test object: 0.5kV-1000kV
Capacitor temperature ≤ 3 × 10-5 / ºC.
Coefficient  Pressure coefficient ≤ 3 × 10-3Mpa
The tangent value of loss angle of capacitor shall not be greater than 3 × 10-5.
The capacitor is filled with SF6 gas At 20 ºC, the pressure is 0.4 ± 0.1MPa.
Installation and operation altitude of the capacitor shall not exceed 1000m
Ambient air temperature shall be - 10 ºC - 40 ºC,
Relative humidity shall not exceed 70%.
Built in large capacity lithium battery Charging voltage 16.8V, charging current 1A.
Charger power supply: 180 ~ 270VAC, 50Hz / 60Hz ± 1% (mains or generator power supply)

More details please contact EPHipot Electric, we have professional tech team to design correctly designed products and systems.


Automatic Hig Voltage High Current Cable Tan Delta and Capacitance Dielectric Loss &amp; Dissipation Factor Tester 10A 1000kv Cable C&Df Tester
Automatic Hig Voltage High Current Cable Tan Delta and Capacitance Dielectric Loss &amp; Dissipation Factor Tester 10A 1000kv Cable C&Df Tester
Automatic Hig Voltage High Current Cable Tan Delta and Capacitance Dielectric Loss &amp; Dissipation Factor Tester 10A 1000kv Cable C&Df Tester
Automatic Hig Voltage High Current Cable Tan Delta and Capacitance Dielectric Loss &amp; Dissipation Factor Tester 10A 1000kv Cable C&Df Tester
Automatic Hig Voltage High Current Cable Tan Delta and Capacitance Dielectric Loss &amp; Dissipation Factor Tester 10A 1000kv Cable C&Df Tester
Automatic Hig Voltage High Current Cable Tan Delta and Capacitance Dielectric Loss &amp; Dissipation Factor Tester 10A 1000kv Cable C&Df Tester
Automatic Hig Voltage High Current Cable Tan Delta and Capacitance Dielectric Loss &amp; Dissipation Factor Tester 10A 1000kv Cable C&Df Tester
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier