• Induced Voltage Test Set Transformer Routine Test Machine for Power Transformer Double Frequency Double Voltage Test Equipment
  • Induced Voltage Test Set Transformer Routine Test Machine for Power Transformer Double Frequency Double Voltage Test Equipment
  • Induced Voltage Test Set Transformer Routine Test Machine for Power Transformer Double Frequency Double Voltage Test Equipment
  • Induced Voltage Test Set Transformer Routine Test Machine for Power Transformer Double Frequency Double Voltage Test Equipment
  • Induced Voltage Test Set Transformer Routine Test Machine for Power Transformer Double Frequency Double Voltage Test Equipment
  • Induced Voltage Test Set Transformer Routine Test Machine for Power Transformer Double Frequency Double Voltage Test Equipment

Induced Voltage Test Set Transformer Routine Test Machine for Power Transformer Double Frequency Double Voltage Test Equipment

Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio
Phase: Three
Certification: ISO9001
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics: High Frequency
Full Protection Functions: Over-Current, Over-Voltage, Zero-Start Light Alarm
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
EP-DVDF
Designed for
Generator Set Controlling
Controlled by
Push Button
Phase and Line
3 Phase 4 Lines
Output Frequency
150Hz
Output Current
15A@30kVA
Rated Capacity
30kVA or at Customized
Output Voltage
800V or at Customized
Generator Input Voltage
380V
Generator Input Frequency
50Hz
Motor Running Current
14A@30kVA
Excitation Current
18A@30kVA
Rated Speed
1480r / Min
Excitation Voltage
185V@30kVA
Excitation Frequency
50Hz
Transport Package
Plywood Case
Specification
1560*480*770
Trademark
EP Hipot Electric
Origin
Wuhan, China
HS Code
9031809090
Production Capacity
500/Year

Product Description

EP-DVDF
Inductive Withstand Voltage (DVDF) Test System

General Information:
DVDF Test System mainly designed for transformer induction withstand voltage test and partial discharge test.

DVDF Control Table:
  • 3 phase 4 lines
  • Controlled by push button.
  • Designed for generator set controlling.
  • High anti interference ability
  • Full protection functions: over-current, over-voltage, zero-starting light alarm.
  • During testing process, press exit button to quit any tests. Press Emergency button if any abnormal happened.
  • Digital voltage/current meter, precision 1.5 degree.
  • Power source: 3 phase
The system is consisted by below units:
  • Generator Motor Set                  EPYZR                   1set
  • Generator Set Controlling Table         EP-DVDF              1set

Motor Generator Set Main Specifications:
 
Power
(kVA)
Output Frequency
(Hz)
Operating Current(A) Exciting Voltage(V) Exciting Current(A) Rated Output Current(A) Rated Output Voltage(V)
30 150 9-14 140-185 15-18 15 800
30 150 9-14 140-185 11-25 9.5 1400
30 100 9-14 140-185 11-18 16 800
40 150 9-11 130-140 18-19 20.1 800
50 150 14-19 130-185 22-30 24.5 800
50 150 14-19 130-185 22-35 32 1400
50 100 14-19 140-185 22-30 16 800
60 150 19-24 100-150 11-18 32.5 800
60 150 19-24 170-220 28-38 22 1400
60 100 19-24 170-220 11-18 33 800
75 150 17-26 210-250 35-42 41 800
75 150 17-26 240-300 40-48 24 1400
75 100 17-26 210-250 34-40 42 800


Rated capacity: 30kVA
Generator input voltage: 380V
Generator input frequency: 50Hz
Generator input current: motor running current 14A, excitation current 18A
Rated speed: 1480r / min
Excitation voltage: 185V
Excitation current: 18A
Excitation frequency: 50Hz
Output voltage: 800V
Output current: 15A
Output frequency: 150Hz

Rated capacity: 40KVA
Generator input voltage: 380V
Generator input frequency: 50Hz
Generator input current: motor running current 15A, excitation current 19A
Rated speed: 1480r / min
Excitation voltage: 140V
Excitation current: 19A
Excitation frequency: 50Hz
Output voltage: 800V
Output current: 23A
Output frequency: 150Hz

Rated capacity: 50kVA
Generator input voltage: 380V
Generator input frequency: 50Hz
Generator input current: motor operating current 19A, excitation current 25A
Rated speed: 1480r / min
Excitation voltage: 150V
Excitation current: 25A
Excitation frequency: 50Hz
Output voltage: 800V
Output current: 24.5A
Output frequency: 150Hz


Rated capacity: 74kVA
Generator input voltage: 380V
Generator input frequency: 50Hz
Generator input current: motor running current 23A, excitation current 35A
Rated speed: 1480r / min
Excitation voltage: 280V
Excitation current: 35A
Excitation frequency: 50Hz
Output voltage: 1400V
Output current: 21.0A
Output frequency: 150Hz



This series can be customized according the customer's requirements. More details on motor generator test set DVDF please contact EP Hipot Electric, we have professional tech team to design correctly designed products and systems.


Induced Voltage Test Set Transformer Routine Test Machine for Power Transformer Double Frequency Double Voltage Test Equipment
Induced Voltage Test Set Transformer Routine Test Machine for Power Transformer Double Frequency Double Voltage Test Equipment
Induced Voltage Test Set Transformer Routine Test Machine for Power Transformer Double Frequency Double Voltage Test Equipment
Induced Voltage Test Set Transformer Routine Test Machine for Power Transformer Double Frequency Double Voltage Test Equipment
Induced Voltage Test Set Transformer Routine Test Machine for Power Transformer Double Frequency Double Voltage Test Equipment
Induced Voltage Test Set Transformer Routine Test Machine for Power Transformer Double Frequency Double Voltage Test Equipment
Induced Voltage Test Set Transformer Routine Test Machine for Power Transformer Double Frequency Double Voltage Test Equipment
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now