12kv Transformer Capacitance Tan Delta Tester 12kv /10kv Transformer Dissipation Loss Tester Cdf Transformer Tester China Supplier

Product Details
Customization: Available
Printer: Build-in Thermal Printer
Anti-Interference Principle: Frequency Conversion
Manufacturer/Factory, Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
>2000 square meters
  • 12kv Transformer Capacitance Tan Delta Tester 12kv /10kv Transformer Dissipation Loss Tester Cdf Transformer Tester China Supplier
  • 12kv Transformer Capacitance Tan Delta Tester 12kv /10kv Transformer Dissipation Loss Tester Cdf Transformer Tester China Supplier
  • 12kv Transformer Capacitance Tan Delta Tester 12kv /10kv Transformer Dissipation Loss Tester Cdf Transformer Tester China Supplier
Find Similar Products

Basic Info.

Model NO.
EPJS-6000
High Voltage Output
0.5kv~12kv
Precision
2%
Maximum Current
200mA
Capacity
2000va
Self-Excitation Power
AC 0V~50V/15A
Automatic Double Frequency
45Hz/55Hz 47.5Hz/52.5Hz 55Hz/65Hz 57.5Hz/62.5Hz
Tg Resolution
0.001%
Cx Resolution
0.001PF
Tg Accuracy
+-(Reading*1.0%+0.040%)
Cx Accuracy
+-(Reading*1.0%+1.00PF)
Tg Measurement Range
Without Limit
Cx Measurement Range
15PF Less Cx Less 300NF
12kv Measurement Range
Cx Less 30 NF
Transport Package
Plywood Case with Foam and Waterproof Plastics
Specification
460*360*350mm
Trademark
EP Hipot
Origin
Wuhan, China
HS Code
9031809090
Production Capacity
500/Year

Product Description

General Information:
EPJS-6000 is a new generation, fully automatic on-site measure dielectric loss(tgδ)and the capacitance (Cx) of electric equipment. It's suitable for testing on transformer, insulating bush, capacitor, CT/PT, MOA etc.

Features:
  • Build-in dielectric loss bridge, frequency conversion power supply, testing transformer, SF6 high stability standard capacitor.
 
  • The test high-voltage source is generated by the inverter inside the instrument and is used for the test object after boosting the voltage from the transformer.
 
  • Frequency can be changed into 50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz. Digital notch technology is adopted to avoid the interference of power frequency electric field to the test.
 
  • Multiple protection of input voltage fluctuation, output short circuit, over-voltage, over-current, temperature, secure and reliable. Meanwhile, it has the function of grounding testing, that voltage boost is not permitted for non-grounding equipment.
 
  • LCD touch screen display. English menu easy to operate.
 
  • 200 groups' data storage. Save testing result according to time order, check history record and print the result.
 
  • Multiple testing mode, with modes of inside high voltage, outside high voltage, inner standard, external standard, GST/UST, self-excitation. High voltage (more than 12kV) dielectric loss test can be made in the situation of external standard outside high voltage.
 
  • Test full sealed CVT (Capacitive Voltage Transformer) C1 and C2 dielectric loss and capacitance at the same time. Also test CVT transformation ratio and voltage angle difference.
 
  • The instrument can accurately measure the CVT dielectric loss value and capacitance value without removing the CVT high voltage lead.
 
  • The dielectric loss and capacitance value of C0 in the upper end of CVT can be measured by using the reverse shielding method.
 
  • High speed sampling signal. Inverter and sampling circuit inside are digitized controlled. Output voltage is adjusted continuously.
Technical Specifications:
Working condition -15ºC~40ºC RH<80%
Anti-interference principle Frequency conversion
Power supply AC 85V~160V Generator can be used
High voltage output 0.5kV~12kV Every 0.1kV
Precision 2%
Maximum current 200mA
Capacity 2000VA
Self-excitation power AC 0V~50V/15A 45HZ/55HZ 47.5HZ/52.5HZ
55HZ/65HZ 57.5HZ/62.5HZ
Automatic double frequency
Resolution tgδ: 0.001%  Cx: 0.001pF
Accuracy △tgδ:±(Reading*1.0%+0.040%)
△Cx :±(Reading*1.0%+1.00PF)
Measurement range tgδ Without limit
Cx 15pF < Cx < 300nF
12kV Cx < 30  nF
5kV Cx < 150 nF
1kV Cx <300 nF
CVT test Cx < 300 nF
CVT ratio range 10~10000
CVT ratio accuracy 0.1%
CVT ratio resolution 0.01
Storage 200 group supports U disk data storage
Dimension Main unit: 350(L)×270(W)×270(H)
Accessory box: 350(L)×270(W)×160(H)
Weight Main unit: 22.75kg
Accessory box: 5.25kg
12kv Transformer Capacitance Tan Delta Tester 12kv /10kv Transformer Dissipation Loss Tester Cdf Transformer Tester China Supplier
12kv Transformer Capacitance Tan Delta Tester 12kv /10kv Transformer Dissipation Loss Tester Cdf Transformer Tester China Supplier
12kv Transformer Capacitance Tan Delta Tester 12kv /10kv Transformer Dissipation Loss Tester Cdf Transformer Tester China Supplier

More details on 12kV C&DF Tester please contact EPHipot Electric, we have professional tech team to design correctly designed products and systems.

12kv Transformer Capacitance Tan Delta Tester 12kv /10kv Transformer Dissipation Loss Tester Cdf Transformer Tester China Supplier
12kv Transformer Capacitance Tan Delta Tester 12kv /10kv Transformer Dissipation Loss Tester Cdf Transformer Tester China Supplier

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier