Customization: | Available |
---|---|
Type: | Storage Battery Tester |
Test Region: | Internal Resistance |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Measuring Range | Max. Display | Resolution | Measuring Accuracy | Measuring Current |
3 mΩ | 3.100 mΩ | 1 uΩ | ±1.0 % rdg. ±10 dgt. | 200 mA |
30 mΩ | 31.00 mΩ | 10 uΩ | ±1.0 % rdg. ±6 dgt. | 200 mA |
300 mΩ | 310.0 mΩ | 100 uΩ | 20 mA | |
3 Ω | 3.100 Ω | 1 mΩ | 2 mA |
Measuring Range | Max. Display | Resolution | Measuring Accuracy |
7 V | ±7.100 V | 1 mV | ±0.1 % rdg. ±6 dgt. |
70 V | ±71.00 V | 10 mV |
Measuring Range | Max. Display | Resolution | Measuring Accuracy |
-10.0ºC~60.0ºC | 60.0ºC | 0.1ºC | ±1.0ºC |
Functions | Battery internal resistance measurement, battery voltage measurement, temperature measurement |
Accuracy guaranteed temperature and humidity | 23ºC±5ºC, below 75%rh |
Power supply | DC 3.7V lithium battery |
Resistance resolution | 1 uΩ |
Voltage resolution | 1 mV |
Temperature resolution | 0.1ºC |
Measuring range | Internal resistance measurement: 0.000mΩ~3.100 Ω (composed of 4 ranges) |
Voltage measurement: 0.000V~±71.00V (consisting of 2 ranges) | |
Temperature measurement: -10.0ºC~60.0ºC (single range configuration) | |
Maximum input voltage | DC 70V (between + measurement terminal and-measurement terminal), no AC input |
Measurement method | Internal resistance measurement: AC 4-terminal test method, open terminal voltage 3V max Measuring current: 2.0mA~200mA (different measuring currents in different ranges) Temperature measurement: NTC temperature sensor (10KΩ at 26ºC) A/D conversion method: successive approximation type Display update frequency: 5 times/second |
Response time | 200ms |
Measure time | About 2 seconds |
LCD size | 70.1mm×52.6mm / 3.5 inches (320*240 resolution 16-bit true color screen) |
Instrument size | LWH: 190mm×121mm×51mm |
USB interface | With USB interface, the stored data can be uploaded to the computer, saved and printed |
Communication | USB |
Hold and store function | There are manual retention and storage, automatic retention and storage |
Alarm function | When the measured value exceeds the alarm set value, an alarm will be issued |
Battery voltage | Real-time display of battery power, reminding to charge in time when battery voltage is low |
Automatic shut-down | There is no operation when power on, and it will automatically power off after about 15 minutes (this function can be turned off in the settings) |
Power consumption | 300mA MIN / 500mA MAX |
Quality | Meter: 480g (including battery) |
Working temperature and humidity | -10ºC~40ºC, below 80%RH |
Storage temperature and humidity | -20ºC~60ºC, below 70%RH |
Insulation resistance | Above 20MΩ (500V between circuit and case) |
Withstand voltage | AC 3700V/RMS (between circuit and case) |
External magnetic field | <40A/m |
External electric field | <1V/m |