Wuhan Transformer Tan Delta test kit power dissipation factor and capacitance measurements
Product Description
General Information:
EPJS-6000 is a new generation, fully automatic on-site measure dielectric loss(tgδ)and the capacitance (Cx) of electric equipment. It's suitable for testing on transformer, insulating bush, capacitor, CT/PT, MOA etc.
Product Parameters
Features:
- Build-in dielectric loss bridge, frequency conversion power supply, testing transformer, SF6 high stability standard capacitor.
- The test high-voltage source is generated by the inverter inside the instrument and is used for the test object after boosting the voltage from the transformer.
- Frequency can be changed into 50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz. Digital notch technology is adopted to avoid the interference of power frequency electric field to the test.
- Multiple protection of input voltage fluctuation, output short circuit, over-voltage, over-current, temperature, secure and reliable. Meanwhile, it has the function of grounding testing, that voltage boost is not permitted for non-grounding equipment.
- LCD touch screen display. English menu easy to operate.
- 200 groups' data storage. Save testing result according to time order, check history record and print the result.
- Multiple testing mode, with modes of inside high voltage, outside high voltage, inner standard, external standard, GST/UST, self-excitation. High voltage (more than 12kV) dielectric loss test can be made in the situation of external standard outside high voltage.
- Test full sealed CVT (Capacitive Voltage Transformer) C1 and C2 dielectric loss and capacitance at the same time. Also test CVT transformation ratio and voltage angle difference.
- The instrument can accurately measure the CVT dielectric loss value and capacitance value without removing the CVT high voltage lead.
- The dielectric loss and capacitance value of C0 in the upper end of CVT can be measured by using the reverse shielding method.
- High speed sampling signal. Inverter and sampling circuit inside are digitized controlled. Output voltage is adjusted continuously.
Technical Specifications:
Working condition |
-15ºC~40ºC |
RH<80% |
Anti-interference principle |
Frequency conversion |
Power supply |
AC 85V~160V |
Generator can be used |
High voltage output |
0.5kV~12kV |
Every 0.1kV |
Precision |
2% |
Maximum current |
200mA |
Capacity |
2000VA |
Self-excitation power |
AC 0V~50V/15A |
45HZ/55HZ 47.5HZ/52.5HZ 55HZ/65HZ 57.5HZ/62.5HZ Automatic double frequency |
Resolution |
tgδ: 0.001% |
Cx: 0.001pF |
Accuracy |
△tgδ:±(Reading*1.0%+0.040%) |
△Cx :±(Reading*1.0%+1.00PF) |
Measurement range |
tgδ |
Without limit |
Cx |
15pF < Cx < 300nF |
12kV |
Cx < 30 nF |
5kV |
Cx < 150 nF |
1kV |
Cx <300 nF |
CVT test |
Cx < 300 nF |
CVT ratio range |
10~10000 |
CVT ratio accuracy |
0.1% |
CVT ratio resolution |
0.01 |
Storage |
200 group supports U disk data storage |
Dimension |
Main unit: 350(L)×270(W)×270(H) |
Accessory box: 350(L)×270(W)×160(H) |
Weight |
Main unit: 22.75kg |
Accessory box: 5.25kg |
Certifications
Packaging & Shipping
Installation Instructions
Company Profile
FAQ
More details on 12kV C&DF Tester please contact EPHipot Electric, we have professional tech team to design correctly designed products and systems.