Secured Trading Service

Automatic Power Transformer Tan Delta and Capacitance Tester 12kv

  • Audited Supplier
  • 8 yrs

Contact Supplier

Product Highlights

  • Wide Voltage Range: Internal HV up to 12kV, External HV up to 12kV, with setting voltage range 0.5~12kV.
  • Anti-Interference Capability: Frequency conversion anti-interference ensures accuracy even under 200% interference.
  • Multiple Test Frequencies: Supports single frequencies (45-65Hz) and auto double frequency conversion modes.
  • Comprehensive Test Applications: Suitable for transformers, insulating bushings, capacitors, CT/PT, and MOA testing.
  • Fast Measurement Speed: Measuring duty takes about 36 seconds depending on the measuring method.
  • Flexible Customization: Offers full, flexible, minor customization and design/sample-based customization options.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Automatic Power Transformer Tan Delta and Capacitance Tester 12kv

Automatic Power Transformer Tan Delta and Capacitance Tester 12kv
Automatic Power Transformer Tan Delta and Capacitance Tester 12kv pictures & photos
Automatic Power Transformer Tan Delta and Capacitance Tester 12kv
Automatic Power Transformer Tan Delta and Capacitance Tester 12kv pictures & photos
Automatic Power Transformer Tan Delta and Capacitance Tester 12kv
Automatic Power Transformer Tan Delta and Capacitance Tester 12kv pictures & photos
Automatic Power Transformer Tan Delta and Capacitance Tester 12kv
  • Automatic Power Transformer Tan Delta and Capacitance Tester 12kv
  • Automatic Power Transformer Tan Delta and Capacitance Tester 12kv
    Automatic Power Transformer Tan Delta and Capacitance Tester 12kv
  • Automatic Power Transformer Tan Delta and Capacitance Tester 12kv
    Automatic Power Transformer Tan Delta and Capacitance Tester 12kv
  • Automatic Power Transformer Tan Delta and Capacitance Tester 12kv
    Automatic Power Transformer Tan Delta and Capacitance Tester 12kv

Find Similar Products

Product Description

General Information: 
EPJS-12kV Capacitance & Disspation Factor Tester is a new generation, fully automatic on-site measure dielectric loss(tgδ)and the capacitance (Cx) of electric equipment. It's suitable for testing on transformer, insulating bush, capacitor, CT/PT, MOA and etc. 


Features: 
  • High accuracy and wide measurement range
  • Automatic measurement process
  • Measures capacitive, resistive or inductive test objects
  • High accuracy ratio measurements
  • Works with any standard capacitor or resistor value without any recalculations
  • All standard UST and GST configurations

Specifications: 
Accuracy:  Cx:  ±(read ×1%+1PF)
Tgδ:  ±(read ×1%+0.00040)
Anti interference:  Frequency conversion anti interference, under 200% interference, still can reach above accuracy. 
Capacitance range:  Internal HV:  3PF~50000PF/12kV 60PF~1μF/0.5kV
External HV:  3PF~1.5μF/12kV 60PF~30μF/0.5kV
Resolution:  Max. 0.001PF, 4 significant figures
Tgδ range:  Unlimited, resolution: 0.001%, capacitance, inductance, resistance can be identified automatically. 
Test current range:  10μA~5A
Inner HV:  Setting voltage range:  0.5~12kV
Max. Output current:  200mA
Increase/decrease voltage:  Continuous slide regulating
Voltage precision:  2%
Voltage resolution:  1V
Test frequency:  45, 50, 55, 60, 65Hz single frequency
45/55Hz, 55/65Hz, 47.5/52.5Hz auto double frequency conversion
Frequency precision:  ±0.01Hz
Outside HV:  UST Positive connection max. Test current 5A, Power frequency or frequency conversion 40-70Hz
GST Negative connection max. Test current: 12kV/5A, power frequency or frequency conversion 40-70Hz
CVT self excitation LV output:  Output voltage 3~50V, output current 3~30A
Measuring duty:  About 36s, it depend on measuring methods
Input power supply:  180V~270VAC, 50Hz/60Hz±1%, local supply or by generator. 
RS232
Build-in thermal printer
Environmental Temperature:  -10ºC~50ºC
Relative humidity:  <90%
Oversize & weight:  460×360×350mm 28kg
Automatic Power Transformer Tan Delta and Capacitance Tester 12kv
Automatic Power Transformer Tan Delta and Capacitance Tester 12kv


More details on 12kV C&DF Tester please contact EPHipot Electric, we have professional tech team to design correctly designed products and systems. 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR259312". Items marked "verified" are certified.

Watch Video
Watch Video
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building 3, Liandong U Valley, Xingsan Road, Hannan District, 430000, Wuhan, Hubei, China
verified Registered Capital
1,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port; Ningbo Port; Guangzhou Port; Shenzhen Port
verified Minimum Order Quantity
1 Set

Our Production Capability & Technical Expertise

Main Products
Transformer Test Equipment, Circuit Breaker Testing Equipment, High Voltage Test System, CT PT Testing and Calibrating, High Voltage Insulation Testing, DC System and Battery Testing, Cable Faults, Test and Diagnostics, Arrester and Insulator Testing
verified Production Lines
3
verified Production Machines
Assembling Line, Testing Line, Winding Line
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instruction but no written records
verified Customization Options
Customization from Designs, Full Customization, Flexible customization, Minor Customization, Customization from Samples
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified Traceability of Raw Materials
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2017-05-18
verified Export Year
8 Years
verified Main Markets
South America, Europe, Australia
verified Repeat Buyers Choice
80%~100%
verified New Products Launched in Last year
Yes

FAQ

What is the warranty period?
We provide a one-year warranty after shipping.
Can the device be customized?
Yes, we offer full customization, flexible customization, minor customization, and customization from designs or samples.
What is the minimum order quantity?
The minimum order quantity is 1 set.
What are the lead times for production?
Both peak season and off-season lead times are within 15 workdays.
What payment methods are accepted?
We accept LC, T/T, D/P, PayPal, Western Union, and small-amount payments.
What after-sales services are provided?
We provide onsite and remote guidance for after-sales service.
What is the maximum output current?
The maximum output current is 200mA for inner HV, and up to 5A or 12kV/5A for outside HV depending on the connection.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now