Ep Hipot Electric Three Channels DC Winding Resistance Tester with Magnetization and Demagnetization Functions

After-sales Service: Onsite and Remote Guidance
Warranty: 1or 2 Years Free Warranty Longlife Service
Max Diameter of Workpiece: <500mm
Mass Scope of Workpiece: <900kg
Type: Handheld
Accuracy Grade: 0.2
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
EPWT-20S
Display
LCD Colour
Control
Computer Control
Weight
10kg
Power Source
220V or 110V at Customized
Three-Phase Test
10A+10A, 5A+5A, 1A+1A
Single-Phase Test
20A, 10A, 5A, 1A, 200mA
Accuracy
+/-0.2 % (+/-2digits)
Max. Resolution
0.1 Uohm
Protection Functions
Full
Working Power Supply
AC220V+-10%, 50Hz+-1Hz
Working Condition
Temperature:0-40 No Condensation
Tester Weight
10.2kg
Magnetization Function
Yes
Demagnetization Function
Yes
RS232
Yes
USB
Yes
Screen
Touch Screen
Data Storage
1000 Groups
Max Consumption
200W
Transport Package
Plywood Case
Specification
428mm* 350mm* 230mm
Trademark
EP Hipot Electric
Origin
Wuhan, China
HS Code
9030332000
Production Capacity
2000/Year

Product Description

EPWT-20S Three channels DC winding resistance tester three phase with magnetization and demagnetization functions

General Information:

The DC resistance of the transformer is a must-test item for the semi-finished product, finished product factory test, installation, handover test and preventive test of the power sector in the transformer manufacturing. Defects and hidden dangers after operation. EPWT-20S three-channel DC winding resistance tester integrates three-phase simultaneous test, magnetization function, and demagnetization function, realizes three-phase simultaneous power-on, independent current sampling, voltage sampling, and simultaneously measures and displays three-phase resistance and three-phase resistance The function of unbalance rate greatly shortens the test time of the DC resistance of the transformer, and solves the problem that the DC resistance test of each tap winding of the power transformer takes a long time.

Features:
  • The instrument can choose the output current value (the maximum output current value is 20A), which is suitable for measuring the inductive DC resistance of transformers and transformers.
  • For large transformers whose five-column core and low-voltage windings are connected in a delta, the instrument can use the method of high and low-voltage series excitation for testing.
  • The instrument is equipped with three-phase measurement function, in order to complete the three-phase direct resistance measurement in one connection of the star-connected winding, and automatically calculate the three-phase unbalance rate, which greatly saves the measurement time and improves the work efficiency. The phase-by-phase test function can also be used to perform phase-by-phase tests on transformers with YN and D(Y) connections until the test is completed.
  • With perfect protection circuit and sound discharge alarm, discharge indication is clear, reducing misoperation.
  • The instrument adopts a 7-inch color touch screen, an English operation interface, and the test data can be displayed in real time.
  • With RS232 communication interface, with the control software of the upper computer, the test data can be transmitted to the background.
  • With a USB interface, the test data can be transferred to a U disk.
  • The instrument has a built-in calendar clock, which can store, recall and print 100 groups of test data.
  • The parameter setting is more perfect, and you can set the test winding, tap position, test phase, test product temperature, converted temperature, etc. of the transformer.
  • The instrument adopts an industrial plastic case, which is easy to carry and prolongs its service life.
Technical Specifications:
 
Measuring Current Three-phase test: 10A+10A, 5A+5A, 1A+1A
Single-phase test: 20A, 10A, 5A, 1A, 200mA
Measuring Range Three-phase test:
10A+10A: 1mΩ~0.5Ω
5A+5A: 2mΩ~1Ω
1A+1A: 10mΩ~5Ω          
Single-phase test:
20A: 0.5mΩ~1Ω
10A: 1mΩ~2Ω
5A: 2mΩ~4Ω
1A: 10mΩ~20Ω
200mA: 100mΩ~100Ω
Measuring Accuracy ±(0.2%+2 digits)
Min. Resolution 0.1μΩ
Power Supply AC220V±10%, 50Hz±1Hz
Working temperature -10~40ºC
Ambient humidity ≤80% RH, no condensation
Oversize 428mm* 350mm* 230mm (L*W*H)
Tester weight 10.2 kg


More details on Transformer Ohmmeter EPWT series please contact EPHipot Electric, we have professional tech team to design correctly designed products and systems.
 

Ep Hipot Electric Three Channels DC Winding Resistance Tester with Magnetization and Demagnetization Functions
Ep Hipot Electric Three Channels DC Winding Resistance Tester with Magnetization and Demagnetization Functions
Ep Hipot Electric Three Channels DC Winding Resistance Tester with Magnetization and Demagnetization Functions
Ep Hipot Electric Three Channels DC Winding Resistance Tester with Magnetization and Demagnetization Functions
Ep Hipot Electric Three Channels DC Winding Resistance Tester with Magnetization and Demagnetization Functions
Ep Hipot Electric Three Channels DC Winding Resistance Tester with Magnetization and Demagnetization Functions

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now